รุ่น DM1182 (ยังไม่รวมภาษีและค่าจัดส่ง)
- รับประกันสินค้า 1 ปี
- ค่าจัดส่ง EMS 60 บาท
- ราคารวมภาษี 7% และค่าส่ง EMS แล้ว
Features
Description
The DM1182 is a high voltage, versatility fully digital stepping drive based on a DSP with advanced control algorithm. It brings a unique level of system smoothness, providing optimum torque and nulls mid-range instability. Motor auto-test and parameter auto-configuration technology offers optimum responses with different motors and easy-to-use. The driven motors can run with much smaller noise, lower heating, smoother movement than most of the drivers on the markets. Its unique features make the DM1182 an ideal solution for applications that require low-speed smoothness.
* Pb-Free or CE/UL approved versions optional. Contact Leadshine or see more information in its hardware manual please.
Specifications
Electrical Specifications (Tj = 25oC/77oF)
Parameters |
DM1182 |
|||
Min |
Typical |
Max |
Unit |
|
Output current |
0.5 |
- |
8.2 (5.9 RMS) |
A |
Supply voltage |
80(113) |
110(155) |
150(212) |
VAC(VDC) |
Logic signal current |
7 |
10 |
20 |
mA |
Pulse input frequency |
0 |
- |
200 |
kHz |
Isolation resistance |
500 |
|
|
MΩ |
Connector P1 Configurations
Pin Functions |
Details |
PUL+ |
Pulse signal: In single pulse (pulse/direction) mode, this input represents pulse signal, each rising or falling edge active (software configurable); 4-5V when PUL-HIGH, 0-0.5V when PUL-LOW. In double pulse mode (pulse/pulse) , this input represents clockwise (CW) pulse,active both at high level and low level (software configurable). For reliable response, pulse width should be longer than 2.5μs. Series connect resistors for current-limiting when +12V or +24V used. The same as DIR and ENA signals. |
PUL- |
|
DIR+ |
DIR signal: In single-pulse mode, this signal has low/high voltage levels, representing two directions of motor rotation; in double-pulse mode (software configurable), this signal is counter-clock (CCW) pulse,active both at high level and low level (software configurable). For reliable motion response, DIR signal should be ahead of PUL signal by 5μs at least. 4-5V when DIR-HIGH, 0-0.5V when DIR-LOW. Please note that rotation direction is also related to motor-driver wiring match. Exchanging the connection of two wires for a coil to the driver will reverse motion direction. |
DIR- |
|
ENA+ |
Enable signal: This signal is used for enabling/disabling the driver. High level (NPN control signal, PNP and Differential control signals are on the contrary, namely Low level for enabling.) for enabling the driver and low level for disabling the driver. Usually left UNCONNECTED (ENABLED). When use it, the ENA signal should ahead the PUL signal at least 100ms due to of soft-start feature of the DM1182. |
ENA- |
|
FAULT+ |
Fault Signal: Open collector fault output. High impedance between FAULT+ and FAULT- during normal operation and low impedance when over-voltage, under-voltage, over-current and phase error protection. MAX: 30VDC, 20mA. |
FAULT- |
Connector P2 Configurations
Pin Function |
Details |
PE |
Recommend connect this port to the ground for better safety. |
AC |
AC power supply inputs. If AC input, recommend use isolation transformers with theoretical output voltage of 80~150VAC. DC input range is 113~212VDC |
AC |
|
A+, A- |
Motor Phase A |
B+, B- |
Motor Phase B |
Microstep & Current
Microstep resolutions and output current are programmable, the former can be set from full-step to 102,400 steps/rev and the latter can be set from 0.5A to 8.2A .
However, when it’s not in software configured mode, this drive uses an 8-bit DIP switch to set microstep resolution, and motor operating current, as shown below:
Microstep Resolution Selection
When it's not in software configured mode, microstep resolution is set by SW5, 6, 7, 8 of the DIP switch as shown in the following table:
Microstep
|
Steps/rev.(for 1.8o motor) |
SW5 |
SW6 |
SW7 |
SW8 |
1 to 512 |
Default/Software configured |
on |
on |
on |
on |
2 |
400 |
off |
on |
on |
on |
4 |
800 |
on |
off |
on |
on |
8 |
1600 |
off |
off |
on |
on |
16 |
3200 |
on |
on |
off |
on |
32 |
6400 |
off |
on |
off |
on |
64 |
12800 |
on |
off |
off |
on |
128 |
25600 |
off |
off |
off |
on |
5 |
1000 |
on |
on |
on |
off |
10 |
2000 |
off |
on |
on |
off |
20 |
4000 |
on |
off |
on |
off |
25 |
5000 |
off |
off |
on |
off |
40 |
8000 |
on |
on |
off |
off |
50 |
10000 |
off |
on |
off |
off |
100 |
20000 |
on |
off |
off |
off |
125 |
25000 |
off |
off |
off |
off |
Current Settings
When it's not in software configured mode, the first three bits (SW1, 2, 3) of the DIP switch are used to set the dynamic current. Select a setting closest to your motor's required current.
Peak Current |
RMS Current |
SW1 |
SW2 |
SW3 |
Default/Software configured (0.5 to 8.2A ) |
OFF |
OFF |
OFF |
|
2.2A |
1.6A |
ON |
OFF |
OFF |
3.2A |
2.3A |
OFF |
ON |
OFF |
4.2A |
3.2A |
ON |
ON |
OFF |
5.2A |
3.7A |
OFF |
OFF |
ON |
6.3A |
4.4A |
ON |
OFF |
ON |
7.2A |
5.2A |
OFF |
ON |
ON |
8.2A |
5.9A |
ON |
ON |
ON |
Typical Connections
Mechanical Specifications (unit: mm [inch])
สอบถามข้อมูลเพิ่มเติมได้ที่
คุณพงษ์ศักดิ์ ป่วนเทียน
เบอร์ 081 3344 239